Комментарии:
Hey bro, just wanted to say thank you! My AC was been down for a month or so.. I called a company to diagnose the issue, and they ended up coming out and telling me it’s not worth the diag due to age (less the 9 year old system) they quoted $17k..
Studied your videos, and decided to tackle it my self..
I found a bad leak on the low side line under my house, at a 90 degree fitting.
Used your videos to learn the recovery process, soldering with staybrite, charging, and checking pressures.
AC going out used to be a huge stresser as a home owner, and I had doubts that could do it... but now that I have the tools and some knowledge.. it’s no big deal.. thanks from a now cold family in Florida❤️
What kind of solder is that. I use sil fos it is much harder.
ОтветитьAwesome tools they make these days! What a change from when I played with this stuff ages ago.
ОтветитьHello,
do the directions say to remove the piston and add a txv, and do they tell you what txv to use on this model?
Staybrite 8 Stronger than Brazing, where is the proof...? Hard to believe..!
ОтветитьSo yes, easier, stronger, Lower temps....... What gets me is the reason why staybrite doesn't come out with a study showing that it's not necessary to also wipe the inside of the pipe. If you look at old water pipes that were not wiped clean while still at the steam stage, they corrode and leak. It would also be great to see compression fitting manufacturers show - as with staybrite- the ac manufacturers that the instructions don't have to say "braze with nitrogen", but they do. so it comes down to yes I can do that very easy, but it voids the warranty.
ОтветитьCan you add staybrite 8 over existing solder, say to fix a leak from a braze joints
ОтветитьHave any recommendations for online training for hvac tech? I already have my 608 universal but want to understand the full functionality amd troubleshooting of standard residential systems
ОтветитьSTRONGER THAN BRAZING lol not
ОтветитьSeems the flux would be pushed into the tube ahead of the solder, as it wicks in. Wouldn't that cause issues?
Ответитьtired of the hvac mafia trying to get their kids braces paid for on one install. I'd gladly pay time and material for an install but they jack the fucking labor way beyond their hourly rate. The hourly rate is supposed to cover all expenses and provide profit and account for any expertise the technicians have. Even if they wanted to charge a flat rate for labor as long as they broke down what that is and they never fucking do.
Ответитьwas that propane or map gas for the torch?
ОтветитьHey great video!!! but here's my Question.. We do alot of splits in mobile homes and from the jump they taught us to check out how many footage on line sets because we would add if needed freon to the system based on how many feet used????
ОтветитьThanks for this great tutorial All your Tutorials are great. So much controversy of brazing versus staybrite. I don’t know if staybrite can be used on the newer A2L systems or not? Are the compressors soldered or brazed from the manufacturers and if one were to replace a compressor with all the movement isn’t it better to Braze?
ОтветитьI noticed a kit on Amazon for like $17 it doesn't mention 8 though will that work?
ОтветитьI'm not a Tech but I used this Staybrite 8 7- years ago when I installed a Complete A/C system and NG furnace. Until today has no issue 😂👍👍,...... I'm still Learning
ОтветитьI have used stay bright 8 for many years, so long can't remember back that far. ON issues.
ОтветитьYou are an inspiring guy. And I guess others might have mentioned, but shouldn't you wear safety goggles (with tinting) while brazing with an acetylene torch?
ОтветитьSo what did you charge to do this work?
ОтветитьLooks good for all joints except compressor outlet through condenser input. Have you ever seen it used on compressor output? Not sure if I would trust it for approaching 300 degs F and lots of vibration stress on compressor high side outlet.
ОтветитьWhen you were running the vacuum pump I saw you removing the valve from suction line. Did u also remove it from liquid line when you placed the micron gauge or do u just leave it on the liquid line and remove it only on suction line. Thx
ОтветитьHey!!!!! I just see your video.
Good job bro I am gonna try it it’s might make the job easy.
Great video!!! Keep=on Keppin On!
ОтветитьI haven't seen the Staybrite 8 here in Korea. I wonder if the Staybrite 8 can be used soldering "aluminum and copper " or "aluminum and aluminum "
Ответитьgood stuff
ОтветитьI'm not an AC guy But I have never seen anyone solder lines sets before, I called my AC guy and he said it would not take the pressure, after reading the comments it sounds like solder works just fine. I think I will give it a try if I ever get the opportunity. I believe its just another attempt at keeping homeowners from installing their own units and keeping the DIY's out of the industry. I live in California and they will not sell me a AC unit at the supply house unless I have my License. Makes me mad.
ОтветитьWhy instead of welding can not use screw on couplers without welding manufacturers should come with screw couplers instead of welding, the heat from welding damage the condensor valve and leak later I have seen it a lot then the condensor valve has to be replaced.
ОтветитьURL for the vaccum ?
ОтветитьGreat video, Goodman doesn't have the best reputation but what could be changed/upgraded easily to bring it up to par? Cap, Contactor, Pressure switches? Everything I've worked on had compromises made, over engineered in some areas and under engineered in others. What weak links if any are in the Goodman product Condenser units? Thanks in advance for any input.
ОтветитьThanks for sharing this video❤🎉
Ответитьهنالك ملاحضه عند اللحام يجب وضع قطعة قماش مبلله على الصمام وشكرا
ОтветитьNavac I just got new gauges I love them and only $89 what a bargain. The only thing that I saw I didn't like is you should be using a swagger and bender no fittings and less joints and where are you no filter driers what do you do about acid build up. But over all nice install I would have made the pipes in the attic tighter to one side so it's not a trip hazard . But like I say all the time never talk about others work because you were not there. Nice job I'm going to find out if that's legal in Florida south Florida that's where I do HVAC work. And there's one more thing why is the txv outside the unit we put inside remember if the Bulb gets hot or cord so will the copper tube carrying the refrigerant correct.
ОтветитьGreat channel, I just subscribed and thanks for what you are doing! When are you going to show how to take your test for HVAC to buy Freon?
ОтветитьNice job.
ОтветитьI notice you using it for new installation. Does Staybrite8 also works with repair that you just torch-remove since it might have old silver residue on them? Thanks for video I think it would be great for TXV install.
Ответитьwhat is the tuck for
ОтветитьWill this torch burn off the old solder from the lines? I don’t want to buy two torches. One to get the old solder off and one for the stay bright
ОтветитьLike watching your videos was wondering the flux doesn't contaminate the refrigerate.
ОтветитьI don't know maybe I'm wrong I'm just a licensed contractor. If I'm not mistaken all the manuals require at least 5% silver brazing rod. Soft solder has to be used with flux. Flux is acid acid gets into the system.
ОтветитьDo not use stay brite #8, it will not last, I work on a unit installed in 1996, I found the leak on the suction at the condenser at the solder joint, I have also found if you use it on a cooler the solder will corrode and leak, the best way to make your connection is braze or pro press!
ОтветитьI’m a transport reefer mechanic. I wanna know if I can use it on thermo king carrier units. It’s like 500 psi
ОтветитьWink if I can buy from Ability refrigerant by cheking the checkbox without actually having an EPA card.- can I buy it for "resale" without the cert?
ОтветитьWhat gas do you use for soldering with Staybright 8? Mapp, Air Acetylene or Oky Acetylene? Is Mapp good enough?
ОтветитьI ve been an hvac tech for 15 yrs, your teaching people the wrong way to do this. I guess people like you keep work coming my way!
ОтветитьSo what is the tool called that you used to remove / install the Schrader Valve without loosing refrigerant? This video Sir, WAS SIMPLY AMAZING, NOT TO MENTION VERY WELL STEP BY STEP EXPLANATIONS ! Solely based upon the MATTER OF MY OPINION, WHICH I CERTAINLY WOULD SAY OTHER VIEWERS WOULD AGREE WITH ME WHEN I SAY, " THIS DIY TUTORIAL VIDEO SHOULD WIN " BEST DIY TUTORIAL VIDEO OF THE YEAR / DECADE", HANDS DOWN ! Thank You Sir, for not only taking the time to make this video but also explaining the process, tools being used & the components thats involved when being worked on / & or installed. AGAIN - SIMPLY MARVELOUS-
VERY WELL REHEARSED/ PLANNED /EXPLAINED/ CLEAR RECORDING WITH VERY CLEAR CRISP NARRATING VOICE THAT COULD BE UNDERSTOOD WITH LITTLW TO NO EFFORTS !!
Your videos rock.
Ответитьhey bro ,I suggest that the valve core must be taken out when welding, which can easily lead to damage to the valve core. refrigerant leak。and..The most reliable welds are high temperature electrodes. Dye aids can aid in welding, and can also seep into the pipes, clogging the system.
Ответить