Комментарии:
Really great Presentation and Explanations - THANK YOU!
ОтветитьI am doing a school project using revit MEP This video really helps me a lot! Thank you
ОтветитьHow I can get this software revit mep ??
ОтветитьI am just learning for fun and I love these videos! 👍
ОтветитьTHANK YOU
ОтветитьGreat Explanations ! Thank you !!!
ОтветитьCan the chiller be substituted by a heat exchanger in a water cooled system ?
ОтветитьThank you very much for useful information
ОтветитьThese videos are awesome!!! i dont have a background in engineering but these videos make it so easy to understand the basics of HVAC!
ОтветитьGreat video with clear explanation!!
ОтветитьThanks for this explanation. Had a question regarding the check valve screen filter installed at the FCU. My check valve screen filter is installed on the return line (after the coils)? Is this right? It seems sensible to have this screen filter to be installed after the shut off valve and before the chilled water enters the FCU. Can you confirm?
ОтветитьI am a mechanical engineer and I just want to let you that your videos are amazing!
ОтветитьGreat video !
ОтветитьThank you a lot for your video lessons. It helps me in English learning because I'm an HVAC engineer from not English speaking country.
ОтветитьThank you for the adequate explanation, but you may have forgotten an important part. In the event of a variable load on cold water through several air treatment units. You need to reduce the speed of the water pump. Therefore, you must control the operation of the water shredder by placing an insulated water tank suitable for the load. It controls the capacity of the shredder through a special temperature regulator or several thermostats depending on the number of compressors in the shredder.
ОтветитьThank so much for your sharing material presentation, it is really useful
Ответитьhi...sorry for personal question...but a kelvion gas cooler with 8 total fans in two rows is being installed at the roof of a supermarket next to my bedroom but 3 metre below. in terms of height..do you think this will make too much noise and the heat from the fans will be damaging...would there be any difference during summer and winter noise and heat levels...thx a lot
ОтветитьIs there water together with the refrigerant inside the chiller? Where is the inlet water coming from that transforms into chilled water for AHU and condenser water for cooling towers? I’m confused
ОтветитьWow
Ответитьvery good 😊
ОтветитьExcellent video! I am a Civil Engineer trying to understand Chilled Water Systems and your videos are the best.
ОтветитьThat was an amazing video.
Ответитьair cooled chiller 500 tons cooling capacity. water cooled chiller 5000 ton cooling capacity.
ОтветитьThank you! I started working at a facility 10 months ago and they have air cooled chillers but are switching to a water cooled chiller. I really didn't understand either system until your video!
ОтветитьProfessor, can you send a link to a simulation program for cooling and heating systems for mechanical and electrical parts and control circuits? Thank you.
ОтветитьBravo
ОтветитьCristal clear explanation I scanned many videos the most informative one is yours, thanks!
ОтветитьI'm a mechanical journeyman at a hospital with 6 giant chillers. I primarily deal with the controls and vav's, but my buddy works on the chillers. It's pretty cool to work on them.
Ответитьgood video
ОтветитьPlease make more videos. You explain things very easy to understand.
ОтветитьPlease what is the boiler function there am a bit confused
ОтветитьWhat is the function of the boiler in the cooled water processe
ОтветитьThanks for explaining.
Ответить🎉🎉
ОтветитьVery educational video, thanks Sir. Can you make also video about Fire Fighting System.
ОтветитьSuperb informative video
ОтветитьAbsolutely talented explanation! I have been in this business for 15 years and you make me love engineering even more. Thank you.
ОтветитьWell Done 👊
Ответитьthanks
ОтветитьFantastic content
ОтветитьExcellent~~~~
ОтветитьThanks for the interesting information. What is the air velocity at the chiller fan outlet? What is the diameter of the chiller fan?
ОтветитьYou are amazing, thank you!!
Ответитьthank you.
ОтветитьExcellenct explanation Sir.
I would really appreciate if you can let me know if the count of chillers operating at a given point of time impacts the AC cooling.
We have got six water chillers installed in a hotel but run only one chiller. AC cooling has significantly reduced as compared to the period when multiple chillers were operating at a time. I am not an HVAC expert but as a layman I am assuming the AC cooling would be enormously enhanced with multiple chillers running at a time.
Thanks again and I look forward to your feedback.
Any recommendation of closed loop water tower manufacturer ?
ОтветитьSimple explanation thank you so much.
ОтветитьI am a Senior Electrical Engineer. Amazing video.................Thanks a lot
ОтветитьHi Mep Academy, could you do a video on the basics of CHW system for data center? I interested on how the loop piping system works. thanks.
ОтветитьMan these videos are fantastic, thanks for making them!!
Ответить