Комментарии:
You know do you ever feel like propress and pex are killing our trade making it to easy so homeowner can do it just wondering if sweating pipe is gonna be obsolete whole reason I became a plumber is fire 🔥😁
Ответить¿Cómo se llama esa herramienta y dónde se puede comprar? Gracias.
ОтветитьDodgy dodgy dodgy
ОтветитьNope don’t like it
ОтветитьI’m curious what the sharpie marks are for before you press it
ОтветитьNo dielectric unions?
ОтветитьThat’s awesome. Great job on installing that expansion tank with the proper bracket..
ОтветитьI would have put a union on hotand cold that way the heater is easier to replace but everything else . Me gusta
ОтветитьGreat job man. Keep’em coming. Glad I found your channel. What model Ridgid Pro-press are you using.
ОтветитьIn which country will such antiques be installed in 2023?
ОтветитьPro press looks cheap to me, I still prefer to solder it up myself. Has the benefit of less copper waste when making repairs as well as just looking better.
That said pro press does have it's place. Like repairing a 2 inch line in a hotel where draining water takes 5 hours.
Did you ever try the pro press x female t’s? Viega definitely makes the best ones. We use them and then just strap the expansion tank with banding iron and stove bolts
ОтветитьNice clean install.
ОтветитьCopper to galvanized pipe should have a dielectric union to prevent rust in a future. Other than that, it looks good 👍
ОтветитьGlad I just retired, it won't be long before some cunt will use these fittings on gas
ОтветитьNeed some music or voice over explaining your process… great werk though (and that’s what’s more important)
ОтветитьSo what’s the purpose of that expansion tank?? I’m not a plumber 👨🔧
Ответитьالله إعاونك وتبارك الله عليك بلومبي فنان....حتى أنا لي نفس الحرفة بلومبي
ОтветитьLove the propress and c1 kit!
ОтветитьWhy didn't you finish the job and replace the flue? Also what was used to prevent electrolysis?
Ответитьthis would fail any inspection. ALL tanks that have 3 inch exhausts must be changed to 4 inch exhaust pipes when swapping out tanks for a new one.
ОтветитьFreakin sweet!!!
ОтветитьRealmente será a prueba de fugas, resistirá alta presión, agua,gas o vapor.
ОтветитьBeautiful
Ответитьin dallas the inspectors need a union nut or flexible hoses if it doesn't pass inspection
ОтветитьAll that to leave an old gate valve installed 🤣
ОтветитьWhere's your vacuum breaker?
ОтветитьCan someone please tell me what that copper clamper tool is called and what brand makes it? I’m sick of soldering
ОтветитьKinda memorized by that tool. I've watched this on a loop
ОтветитьBrass fitting between galvanized and copper tubing and your good. If you want to take it a step further… a union and a ball valve to replace expansion tank would be nice.
ОтветитьGood installation but the guy is not using dielectric unions smh.
Ответить😂 На от.бись, вообще есть специальный флюс с припоем и эта вся песня Паяется.
ОтветитьGonna suck if you have to remove the water heater. No unions.
Ответитьpush and pulls baby we love them!
ОтветитьMuy buen trabajo felicitaciones, el único detalle faltan unas tuercas union para futuros mantenimientos solo eso pero de lo demás es excelente
ОтветитьPlease put a finger between those jawz and show the result for safety sake? Ty...
ОтветитьWHAT ?
Will those unions hold pressure ???
This dude obviously doesn't know what he is doing, sure he has a new toy but with no dielectric unions on the galvanized pipe connections it's going to rot through plus if we're me I would solder all the joints - he probably can't solder .
ОтветитьI hate this crap now what do you do if it’s a emergency
ОтветитьWhat? No isolation valves?
ОтветитьLol why are you using the C1 head for easily accessible fittings?
ОтветитьLooks clean and good on you for knowing to mark your fittings on pro press. Only gripe is the way you mounted the expansion tank. If/when that fills with water that’s going to put a lot of tension on that long piece of copper you used.
ОтветитьNow that’s how I call making money on a water heater
ОтветитьNo good. Tank wrong way, can’t drain out or be flushed. Bladder will be toast premature
ОтветитьOnly angle jaws no regular jaws? (Just asking because we have both and the regular jaws are easier sometimes)
Ответить🤦🏽 I know this is a stupid question, but can you still flux and solder joint later on if leaks occur?
ОтветитьMy question is why make it so hard to replace the water heater? I’ve seen water heaters installed with just a channel lock and a pipe wrench
ОтветитьId just sweat on male adapters and run stainless flex lines
ОтветитьYou would of made an extra $20 on that job if you knew how to solder. That could add up to $300-400 per week or $15-20k per year.