Harmonics: What are they, why do I care, how do I solve?

Harmonics: What are they, why do I care, how do I solve?

ABB Drives US

11 лет назад

234,766 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@vahidbakhtiari4221
@vahidbakhtiari4221 - 23.05.2017 19:44

How can I download the slides? Is there any book or article I can read and learn more?

Ответить
@AlexTian-1990
@AlexTian-1990 - 31.01.2024 04:47

Good Video!

Ответить
@RamaDevi-zm2rx
@RamaDevi-zm2rx - 12.11.2022 14:38

Recent disasters due to harmonies

Ответить
@reysee
@reysee - 07.08.2022 19:46

I enjoy Chris Pratt talking about harmonics.

Ответить
@busraahmed1708
@busraahmed1708 - 05.08.2022 06:43

ABB means please

Ответить
@garbo8962
@garbo8962 - 26.04.2022 15:38

Retired from a large hospital and never know they are held to a tighter voltage distortion. Had hundreds of drives from 3 to 1750 HP and our great start up tech said that we were the only place that had equipment on line side & load side of most drives dealing with harmonics and voltage distortion. About 5 years ago at an IAEI class they said Japan is experimenting with supplying DC panels to large buildings. This would eliminate the need for rectifier and cheaper power supplies to equipment and reducing air conditioning loads. Think they hope to save at least 5% over all between power & AC savings.

Ответить
@garbo8962
@garbo8962 - 26.04.2022 15:28

Two things: Do 18 pulse VFD'S produce or handle harmonics better then they standard 6 pulse drives? Read some where that some cheap cheating china LED'S have a low power factor as low as 0.5 . Do such low power factor LED''S produce more harmonics then one say above 0.9 PF?. Tech from two separate drive companies said to stay away from 18 pulse drives but we have a lot of them in a new 12 story building ( all drives 30 HP & higher have 18 pulse drives except for soft start on 200 HP fire pump ). Do the newer think they are called active line reactors with their contactors & capacitors much better then plain Jane line reactor? Thanks for nice vid.

Ответить
@pareshpatel7385
@pareshpatel7385 - 06.10.2021 05:46

Nice topic
Will you please describe effects of non linear loads on DG sets as when ever I operate non linear load from grid to DG lod has variation in kw but still incoming DG voltage was not so varying

Ответить
@erikhastenreiter1676
@erikhastenreiter1676 - 29.08.2021 15:10

good nice

Ответить
@imeprezime1285
@imeprezime1285 - 21.04.2021 11:44

Power factor and voltage drop. If these are acceptable I don't give a damn for harmonics

Ответить
@mattaparthisrivenkateswara7021
@mattaparthisrivenkateswara7021 - 01.04.2021 06:13

Very good and simple for understanding thank you

Ответить
@BlueLightRhyno
@BlueLightRhyno - 31.03.2021 23:04

Thnks!!

Ответить
@johndunston2394
@johndunston2394 - 06.02.2021 20:22

Very nice presentation. Thanks

Ответить
@aatirehrarsiddiqui8894
@aatirehrarsiddiqui8894 - 30.12.2020 21:03

Great video. Neat and articulate.

Ответить
@sohailjanjua123
@sohailjanjua123 - 09.12.2020 16:32

Hi Jeff, I like youe lecture

Ответить
@phasorsystems6873
@phasorsystems6873 - 09.06.2020 18:20

Kirchoff's laws got you awake at night? Search for androidcircuitsolver on google

Ответить
@thangapandiarajapandian1741
@thangapandiarajapandian1741 - 25.05.2020 23:45

Great Video, Thank You

Ответить
@harrisonmixer9583
@harrisonmixer9583 - 31.01.2020 23:00

You're camera guy sucks, I didn't see a damn thing you were pointing to.

Ответить
@alexanderyousefian3186
@alexanderyousefian3186 - 30.12.2019 05:25

Jeff really great and informative video, just recently had to sink my teeth to all of this information dealing with harmonics and this was a great video explaining some of the main concepts. Keep up the great work!

Ответить
@sankareee93
@sankareee93 - 16.09.2019 11:17

Thank you very much this very important lecture about harmonic i really like this lecture

Ответить
@Muck-qy2oo
@Muck-qy2oo - 21.02.2019 17:38

And how do subharmonics work?

Ответить
@yehiaelrifai2545
@yehiaelrifai2545 - 07.02.2019 23:07

Do you recommend to avoid VFD operated large chillers in data center application?

Ответить
@ervivekchoubey
@ervivekchoubey - 30.03.2018 17:02

Thanks for this superb presentation. As an electrical engineering undergrad, I had some doubts regarding harmonics and its effects. By the end of the video, I learned something.

Ответить
@sri279
@sri279 - 29.03.2018 21:20

Thank you very much for uploaded this..

Ответить
@JohnSmith-ed1sr
@JohnSmith-ed1sr - 20.03.2018 18:35

How are you determining Voltage distortion by looking at the current waveform. In the begining you explain the calculation for ITHD then magically 30 seconds latter in the transformer comparison slides you come up with a voltage distortion value with no explanation of how you got it

Ответить
@omidash267
@omidash267 - 12.11.2017 23:01

I was thinking 70 + 20 = 90, Today I learn 70 + 20 = 72, and it responded to all my THD Math I knew before :)

Ответить
@othusitselokailwe2857
@othusitselokailwe2857 - 28.09.2017 00:26

Nice presentation but we are more interested on what he is explaining. Now you guys are showing more of him instead of the slides

Ответить
@kakadiatalshi5442
@kakadiatalshi5442 - 22.04.2017 11:54

Please be noted that Higher capacity transformers has comparatively Low impedance but not the higher impedance and that's why it exhibit low voltage distortion against same harmonic current Bcoz V=ZI , so less the Z, less the V@same I .
In the video you stated that higher capacity transformer has higher impedance which needs to be corrected otherwise nice lecture. Thank you.

Ответить
@jesterraj
@jesterraj - 22.04.2017 02:52

can a generator create harmonic distortion?

Ответить
@mikemiller5534
@mikemiller5534 - 12.03.2017 02:39

Great video! Thanks Jeff

Ответить
@seshutatikola3883
@seshutatikola3883 - 16.02.2017 02:11

jeff Great presentation keep uo the good work

Ответить
@tacarn
@tacarn - 25.01.2017 10:28

Can harmonic distortion be generated from poorly designed generators? (alternators) Say for instance, from a poorly designed wind generator that had harmonic content?

Ответить
@MR-nl8xr
@MR-nl8xr - 27.12.2016 03:43

55 Deg. that's freaking cold.

Ответить
@deokagusti8981
@deokagusti8981 - 30.11.2016 18:26

Very helpful! thanks Jeff

Ответить
@APprojection
@APprojection - 17.08.2016 10:22

Thanks a lot, very useful

Ответить
@FrozenArchLich
@FrozenArchLich - 02.03.2016 08:14

I'm in the middle of making a switching PSU. What I've just heard is extremely helpful to my job. Thank you for sharing valuable knowledge. ^_^

Ответить
@MrYasir966
@MrYasir966 - 10.11.2015 06:22

very helpful, many thanks Jeff.

Ответить
@malou5290
@malou5290 - 11.10.2015 08:17

sinaserdal

Ответить
@enjay2139
@enjay2139 - 09.07.2015 18:34

Great video, but one thing I observed that most of the time the slide was not shown while you were pointing to the slides, making it missed out what you were trying to show. The camera was focused on you instead of the screen. Can you fix it please? or is it too late.

Ответить
@mohdredduanmaddom7160
@mohdredduanmaddom7160 - 16.03.2015 19:10

great video  jeff , make me more understand on harmonic 

Ответить
@niallstone9563
@niallstone9563 - 16.02.2015 02:14

Great video Jeff, thank you.

Ответить
@josephidehen129
@josephidehen129 - 22.01.2015 04:02

Great presentation!

Ответить
@DaneDuPlessis
@DaneDuPlessis - 28.02.2014 18:07

Helpful insights, thanks Jeff.

Ответить
@SafeAndEffectiveTheySaid
@SafeAndEffectiveTheySaid - 17.11.2013 01:09

Thank you!

Ответить